Liquid-Heating Kitchen Appliances Standards Update Announcement
According to the CSA standard Update Bulletin No. 46 (issued: Feb., 24, 2015), the current standards CSA C22.2 No. 64 and CSA C22.2 No. 1335.2.15 for liquid-heating Kitchen appliances appliances will be replaced by CSA C22.2 NO. 60335-2-15 after June 01, 2017.
Because the requirements of CSA C22.2 No. 1335.2.15 and CSA C22.2 NO. 64 are similar, only the main differences between CSA C22.2 No. 64 and CSA C22.2 No. 60335-2-15 are listed as below for your reference.
Please be kindly noted, the appliances that other than liquid-heating kitchen appliance not include in this announcement, the standards maintained.
1. Standard Scope
CSA C22.2 No. 64
|
CSA C22.2 No. 60335-2-15
|
This standard applies to kitchen-type cooking and liquid-heating appliances in household
and similar applications, also applies to miscellaneous equipment such as aquarium heaters, facial saunas and etc.
|
This standard applies to kitchen-type cooking and liquid-heating appliances in household and similar applications.
Such as:
– coffee-makers;
– cooking pans;
– egg boilers;
– feeding-bottle heaters;
– kettles and other appliances for boiling water, having a rated capacity not exceeding 10 L;
– milk heaters;
– pressure cookers having a rated cooking pressure not exceeding 140 kPa and a rated capacity not exceeding 10 L;
– rice cookers;
– slow cookers;
– steam cookers;
– soy milk makers;
– tea maker;
– wash boilers;
– yoghurt makers
|
2. Insulation Classification
CSA C22.2 No. 64
|
CSA C22.2 No. 60335-2-15
|
- appliances designed for outdoor use;
- all appliances intended to be immersed fully or partially in water for cleaning and/or during use;
-appliances (other than the electrode type) that are not designed to be immersed in water but might be immersed or partially immersed for cleaning and/or during use, such as slow cookers with non-removable liners.
All of above products shall be provided with grounding connector.
|
- Cooking pans;
- kettles;
- pressure cookers;
- rice cookers;
- slow cookers;
- steam cookers;
- and all appliances intended to be immersed fully or partially in water for cleaning and/or during use
All of above products shall be class I, class II, or class III.
All other products shall be class 0, class I, class II, or class III.
But class 0 products shall not exceed 150 volts (rms) to ground.
|
3. Power Supply Cord
CSA C22.2 No. 64
|
CSA C22.2 No. 60335-2-15
|
Type of flexible cord and Length:
The requirements of CSA C22.2 No. 60335-2-15 same as CSA C22.2 No. 64
|
Strain relief:
|
90N
|
Same as IEC 60335-1
|
Flexing:
|
CSA C22.2 No. 60335-2-15:
For the appliances provided with a SUPPLY CORD that are moved while in operation, the requirements of CSA C22.2 No. 60335-2-15 same as IEC 60335-1;
Others, same as CSA C22.2 No. 64.
|
4. Moving Internal Wires or Connectors
CSA C22.2 No. 64
|
CSA C22.2 No. 60335-2-15
|
The wiring will subject to flexing
in the normal use: 6000 cycles.
|
The wiring or connector will subject to flexing during normal use: 10 000cycles;
The wiring or connector will subject to flexing during user maintenance: 100cycles.
|
5. Spacing
CSA C22.2 No. 64
|
CSA C22.2 No. 60335-2-15
|
In CSA C22.2 No. 60335-2-15, the minimum clearances and creepage distances in class 0 appliances shall be the greater of that determined in CSA C22.2 No. 60335-2-15 and CSA C22.2 No. 64;
In CSA C22.2 No. 60335-2-15, the minimum clearances and creepage distances for all other than class 0 appliances, shall be follow the requirements of CSA C22.2 No. 60335-1.
|
6. Opening on Enclosure
CSA C22.2 No. 64
|
CSA C22.2 No. 60335-2-15
|
For moving parts and live parts:
|
Use Figure 1:
|
Same as IEC60335-1。
Except:
The articulated probe of UL when the product is:
a) A hand-held product, or a hand-held part of a product, or
b) Accessible to children while the product is operating.
|
Opening in bottom enclosure:
The requirements of CSA C22.2 No. 60335-2-15 same as CSA C22.2 No. 64.
|
7. Drainage Opening
CSA C22.2 No. 64
|
CSA C22.2 No. 60335-2-15
|
No size was required in CSA C22.2 No.64, judging by test.
|
Same as IEC 60335-1, drain holes shall be at least 5 mm in diameter or 20 mm2 in area with a width of at least 3 mm.
|
8. Mechanical Strength
CSA C22.2 No. 64
|
CSA C22.2 No. 60335-2-15
|
0.54Kg steel ball, force 1J
|
Use 0.54Kg steel ball, force 2J
|
Push and pull for NON-DETACHABLE PARTS: None
|
Push and pull for NON-DETACHABLE PARTS: same as IEC60335-1
|
Water Kettle Drop Test:
The test method of CSA C22.2 No. 64 was cited to CSA C22.2 No. 60335-2-15.
|
9. Plug Discharge Test
CSA C22.2 No. 64
|
CSA C22.2 No. 60335-2-15
|
None
|
Same as IEC 60335-1, the voltage shall not exceed 34 V
|
10. Moisture Resistance
CSA C22.2 No. 64
|
CSA C22.2 No. 60335-2-15
|
The test method of CSA C22.2 No. 60335-2-15 same as the IEC 60335-1 and IEC 60335-2-15, so all tests may be redone, when CSA C22.2 No. 64 is replaced by CSA C22.2 No. 60335-2-15.
|
11. Power Input
CSA C22.2 No. 64
|
CSA C22.2 No. 60335-2-15
|
≤50 W: - 25W / +10W;
>50 W: –10% / +5%
|
Same as IEC 60335-1
|
12. Normal Temperature Test and Abnormal Test
CSA C22.2 No. 64
|
CSA C22.2 No. 60335-2-15
|
The test method of CSA C22.2 No. 60335-2-15 same as the IEC 60335-1 and IEC 60335-2-15, so all tests may be redone, when CSA C22.2 No. 64 is replaced by CSA C22.2 No. 60335-2-15.
|
13. Leakage current and electric strength
CSA C22.2 No. 64
|
CSA C22.2 No. 60335-2-15
|
The test method of CSA C22.2 No. 60335-2-15 is similar as the IEC 60335-1 and IEC 60335-2-15, so the Dielectric Strength Test and Leakage Current Test may be redone, when the CSA C22.2 No. 64 replaced by CSA C22.2 No. 60335-2-15. And when the Dielectric Strength Test and Leakage Current Test are cited as the criterion of test result for all other test, although the test method of CSA C22.2 No. 60335-2-15 are same as CSA C22.2 No. 64, the all other test may be redone.
|
14. Coupler of Cordless Appliance
CSA C22.2 No. 64
|
CSA C22.2 No. 60335-2-15
|
None
|
for cordless kettles, 10 000 times
for cordless coffee makers, 10 000 times
for other cordless appliances, 6 000 times
|
15. Critical Components
CSA C22.2 No. 64
|
CSA C22.2 No. 60335-2-15
|
Component requirements of CSA C22.2 No. 60335-2-15 shall be follow the requirements of CSA standards.
|
16. Ball-pressure test and glow-wire test and EMP Test
CSA C22.2 No. 64
|
CSA C22.2 No. 60335-2-15
|
None
|
Same as IEC 60335-1
|
Remark
For those ETL certificates issued, we will evaluate the possible influence that caused by this standard update, and will notice you as soon as possible, in order to keep your certificate latest and valid.
Our service
-
Intertek can issue ETL certification mark through testing to the UL standard, or the US national standard and CSA standard, or Canada standard, helping the clients’ products enter the North America market faster, efficiently and safely.
-
Faster safety testing delivery time (average turnaround only 15 days), wide range of services, leading expertise and capacity in product safety, energy efficiency, performance, chemical and bench marking testing, being the trust worthy partner of many world leading brands
-
Intertek has a strong presence in China with laboratories and offices in many cities including Shanghai, Shenzhen, Hangzhou, Xiamen, Wenzhou, Cixi, Dalian, Qingdao etc, offering fast and convenient local service to Chinese manufacturers.
About Intertek
Intertek is a leading Total Quality Assurance provider to industries worldwide. Our network of more than 1,000 laboratories and offices and more than 100 countries, delivers innovative and bespoke Assurance, Testing, Inspection and Certification solutions for our customers’ operations and supply chains. Intertek Total Quality Assurance expertise, delivered consistently with precision, pace and passion, enabling our customers to power ahead safely.
www.intertek.com.cn
|
|